Frequency range: 1 MHz to 6 GHz
Dynamic range: 119 dB, typ.
Output power range: -40 ... 0 dBm
Measured parameters: S11, cable losses / S11, |S21|, |S12|, S22 (when using two reflectometers)
Number of ports: 1
Impedance: 50 Ohm
Measurement time per point: 100 µs
Key Features:
• Compact and lightweight 1-port Analyzer
• Direct connection to device - no test cable required
• USB-powered
• Basic measurement capabilities: Reflection coefficient magnitude and phase, Cable loss, Time domain analysis with gating (Distance to fault)
• Calibrating with mechanical kit or Automatic Calibration Module
• Windows/Linux-based touchscreen-oriented Software
• Software remote control via SCPI (over HiSLIP or TCP/IP Socket) and COM/DCOM
Optional measurement capabilities:
1NX-VNA - Transmission magnitude measurement using 2 reflectometers



Frequency range: 85 MHz to 15 GHz
Dynamic range: 125 dB (up to 4.8 GHz) / 105 dB (from 4.8 GHz), typ.
Output power range: -25 … 0 dBm
Measured parameters: S11, cable losses / S11, |S21|, |S12|, S22 (when using two reflectometers)
Number of ports: 1
Impedance: 50 Ohm
Measurement time per point: 170 µs
Key Features:
• Compact and lightweight 1-port Analyzer
• Direct connection to device - no test cable required
• USB-powered
• Basic measurement capabilities: Reflection coefficient magnitude and phase, Cable loss, Time domain analysis with gating (Distance to fault)
• Calibrating with mechanical kit or Automatic Calibration Module
• Windows/Linux-based touchscreen-oriented Software
• Software remote control via SCPI (over HiSLIP or TCP/IP Socket) and COM/DCOM
Optional measurement capabilities:
1NX-VNA - Transmission magnitude measurement using 2 reflectometers



Frequency range: 0.3 MHz to 1.3 GHz
Dynamic range: 130 dB, typ.
Output power range: -55 ... +3 dBm
Measured parameters: S11, S21
Number of ports: 2
Impedance: 50 Ohm
Measurement time per point: 150 μs



Frequency range: 100 kHz to 4 GHz
Dynamic range: 133 dB, typ.
Output power range: -50 ... +10 dBm
Measured parameters: S11, S21, S12, S22
Number of ports: 2
Impedance: 75 Ohm
Measurement time per point: 24 μs
Optional measurement capabilities:
• AFR-X - Automatic Fixture Removal



Frequency range: 9 kHz to 1.5 GHz
Dynamic range: 137 dB, typ.
Output power range: -55 ... +5 dBm
Measured parameters: S11, S21, S12, S22
Number of ports: 2
Impedance: 50 Ohm
Measurement time per point: 24 μs
Key Features:
• Uncompromising parameters in compact and lightweight form factor
• Active and passive components and devices measurement
• Basic measurement capabilities: S-parameters and absolute power measurement, time domain analysis with gating, frequency converting devices measurement
• Calibrating with mechanical kit or Automatic Calibration Module
• Windows/Linux-based Software
• Software remote control via SCPI (over HiSLIP or TCP/IP Socket) and COM/DCOM
Optional measurement capabilities:
• ACP-X - Compression point measurement
• AFR-X - Automatic Fixture Removal
• PLS-X - Pulsed measurement



Frequency range: 9 kHz to 3 GHz
Number of ports: 2
Dynamic range: 137 dB, typ.
Output power range: -55 ... +5 dBm
Measured parameters: S11, S21, S12, S22
Impedance: 50 Ohm
Measurement time per point: 24 μs
Key Features:
• Uncompromising parameters in compact and lightweight form factor
• Active and passive components and devices measurement
• Basic measurement capabilities: S-parameters and absolute power measurement, time domain analysis with gating, frequency converting devices measurement
• Calibrating with mechanical kit or Automatic Calibration Module
• Windows/Linux-based Software
• Software remote control via SCPI (over HiSLIP or TCP/IP Socket) and COM/DCOM
Optional measurement capabilities:
• ACP-X - Compression point measurement
• AFR-X - Automatic Fixture Removal
• PLS-X - Pulsed measurement



2C199, Silk Road Cultural Commodity City, Baktu Port Border Trade Zone, Tacheng City, Xinjiang

13581910802