Frequency range: 0.3 MHz to 1.3 GHz
Dynamic range: 130 dB, typ.
Output power range: -55 ... +3 dBm
Measured parameters: S11, S21
Number of ports: 2
Impedance: 50 Ohm
Measurement time per point: 150 μs



Frequency range: 100 kHz to 4 GHz
Dynamic range: 133 dB, typ.
Output power range: -50 ... +10 dBm
Measured parameters: S11, S21, S12, S22
Number of ports: 2
Impedance: 75 Ohm
Measurement time per point: 24 μs
Optional measurement capabilities:
• AFR-X - Automatic Fixture Removal



Frequency range: 9 kHz to 1.5 GHz
Dynamic range: 137 dB, typ.
Output power range: -55 ... +5 dBm
Measured parameters: S11, S21, S12, S22
Number of ports: 2
Impedance: 50 Ohm
Measurement time per point: 24 μs
Key Features:
• Uncompromising parameters in compact and lightweight form factor
• Active and passive components and devices measurement
• Basic measurement capabilities: S-parameters and absolute power measurement, time domain analysis with gating, frequency converting devices measurement
• Calibrating with mechanical kit or Automatic Calibration Module
• Windows/Linux-based Software
• Software remote control via SCPI (over HiSLIP or TCP/IP Socket) and COM/DCOM
Optional measurement capabilities:
• ACP-X - Compression point measurement
• AFR-X - Automatic Fixture Removal
• PLS-X - Pulsed measurement



Frequency range: 9 kHz to 3 GHz
Number of ports: 2
Dynamic range: 137 dB, typ.
Output power range: -55 ... +5 dBm
Measured parameters: S11, S21, S12, S22
Impedance: 50 Ohm
Measurement time per point: 24 μs
Key Features:
• Uncompromising parameters in compact and lightweight form factor
• Active and passive components and devices measurement
• Basic measurement capabilities: S-parameters and absolute power measurement, time domain analysis with gating, frequency converting devices measurement
• Calibrating with mechanical kit or Automatic Calibration Module
• Windows/Linux-based Software
• Software remote control via SCPI (over HiSLIP or TCP/IP Socket) and COM/DCOM
Optional measurement capabilities:
• ACP-X - Compression point measurement
• AFR-X - Automatic Fixture Removal
• PLS-X - Pulsed measurement



Frequency range: 9 kHz to 4.5 GHz
Number of ports: 2
Dynamic range: 135 dB, typ.
Output power range: -55 ... +5 dBm
Measured parameters: S11, S21, S12, S22
Impedance: 50 Ohm
Measurement time per point: 24 μs
Key Features:
• Uncompromising parameters in compact and lightweight form factor
• Active and passive components and devices measurement
• Basic measurement capabilities: S-parameters and absolute power measurement, time domain analysis with gating, frequency converting devices measurement
• Calibrating with mechanical kit or Automatic Calibration Module
• Windows/Linux-based Software
• Software remote control via SCPI (over HiSLIP or TCP/IP Socket) and COM/DCOM
Optional measurement capabilities:
• ACP-X - Compression point measurement
• AFR-X - Automatic Fixture Removal
• PLS-X - Pulsed measurement



Frequency range: 9 kHz to 6.5 GHz
Number of ports: 2
Dynamic range: 135 dB, typ.
Output power range: -55 ... +5 dBm
Measured parameters: S11, S21, S12, S22
Impedance: 50 Ohm
Measurement time per point: 24 μs
Key Features:
• Uncompromising parameters in compact and lightweight form factor
• Active and passive components and devices measurement
• Basic measurement capabilities: S-parameters and absolute power measurement, time domain analysis with gating, frequency converting devices measurement
• Calibrating with mechanical kit or Automatic Calibration Module
• Windows/Linux-based Software
• Software remote control via SCPI (over HiSLIP or TCP/IP Socket) and COM/DCOM
Optional measurement capabilities:
• ACP-X - Compression point measurement
• AFR-X - Automatic Fixture Removal
• PLS-X - Pulsed measurement